BUY ONLINE



Cooling water pumps

Application: Gwynnes 42” Vertical Cooling water Pumps 8 off
Old sealing method: James Walker rotalion
New Sealing method: Chesterton 442 Split Mechanical seal 7.00” shaft sealing

 

Problem:

Excessive leakage from old sealing method on bottom glands causing bearing contamination and short life.

Objective:

To install a reliable leak free sealing solution with capability to service without pump tear down.

Result:

4 pumps done to date 1st one January 04 running leak free all other pumps to be done   on scheduled outages