BUY ONLINE



Fiber line Oxygen Mixer

Application: Sunds Stock Oxygen Mixer
Sealing Method: Chesterton 1400R Graphite Packing/Spiraltrac Version P

 

Problem:

Continual excessive stock leakage especially on Eucalyptus Fiber variety. This caused twin lantern ring blockages and subsequent loss of seal water causing packing failure.

Objective:

Re engineer Gland set up to gain Packing reliability on Eucalyptus fiber, whilst reducing seal water flow into product.

Result:

Gland Reliability achieved and now operating for 18 months from installation with occasional adjustments.